Physiology & Neuroscience      Electronics   Pulmonary 
 1-800-426-1306
Instruments
· Amplifiers
· Stimulators
· Specialty
Data Acquisition and Analysis
Adapters & Connectors
Alligator Clips
Cables & Test Leads
Capillary Glass
Cryostats & Microtomes New
Dental Cement
Electrodes
Illuminators
Liquid Handling New
Microscopes On Sale!
Pin Connectors
Pipettors New
Tubing
Wire & Rod
Shopping Cart
Chat     Help
Login / New Account
 
WHAT'S NEW! PRODUCT LIST DOWNLOADS FAQs SERVICE SURPLUS
Table of Contents
• Request a Catalog
• Customer Survey

Selection Tools
Model 3600 16-Channel Extracellular AC Amplifier
On-Board Touch Screen Control

Settings of the various features of the amplifier can be set either by the touchscreen LCD on the unit itself, or by a PC compatible computer program.

Below are screen captures of a few of the on-board control screens.

The CHANNEL EDIT SCREEN is used to edit the parameters of the amplifier channels. The top line of the CHANNEL EDIT SCREEN (as well as all other screens) is the TOOLBAR, which contains navigation icons that allow the user to navigate to key screens. The horizontal SINGLE CHANNEL SELECT LIST selects the channel whose current settings are displayed in the vertical parameter lists (High Pass, Low Pass, Gain, Notch, Reference, and Mode).

Pressing any value displayed in any list will highlight that value, and will immediately set that channel's parameter to the selected value. Thus, this is the equivalent action of turning a dial or a knob on traditional amplifiers.

If desired, it is possible to copy the parameters of this selected channel to any or all of the remaining channels. Simply select which channels you would like the parameters copied to by highlighting the channel numbers in the double rows of the MULTICHANNEL SELECT LIST at the bottom of the EDIT SCREEN. Pressing COPY will then transfer the channel parameters to the selected channels.
Pressing 16 at the top of any screen will display the 16-CHANNEL VIEW screen. The first 16-Channel view displays the most commonly changed parameters (High Pass Filter, Low Pass Filter, and Gain settings) of all 16 channels. Pressing the arrow in the lower right-hand corner will switch the display to the other parameters (Notch, Common Reference, and Mode).
Options on the MAIN MENU screen are grouped according to four main functions: Program, Amplifier, User Prefs, and Firmware settings. Program functions include loading and saving 16-channel parameter sets for later recall (LOAD, SAVE), determining which of the stored parameter sets will be initially loaded upon instrument boot-up (SET START-UP PROGRAM), and naming the instrument (INSTRUMENT NAME). Amplifier functions include setting the Common Reference type
( (-)INPUT ), applying the Notch filter if necessary (NOTCH FILTER), determining required parameters for passing stimulating current through the instrument (STIMULATION INPUT), and generating a signal to be used to calibrate the amplifier or other instruments (CALIBRATION SIGNAL). User Prefs options include a variety of controls related to the LCD display (LCD SETTINGS), calibrating the touch-screen for a given user's finger placement (CALIBRATE LCD), and determining the preferred STARTUP PAGE. Firmware options enable the user to identify which version of firmware and software is currently loaded on the instrument.
 
Note: A-M Systems Instruments are NOT approved for use with Human Subjects in either a Clinical or Research Environment.
Catalog
Number
DescriptionPriceQuantity
Ordered
Item
Sub-Total
1 - 45+
960000Model 3600 16-Channel Extracellular Amplifier$6,745.00$6,407.75$0.00
962000Model 3600 Headstage, 16-Channel, Record / Stimulate$1,725.00$1,552.50$0.00
962050Model 3600 Stimulation Control Cable, for 16-Channel Stim/Record Headstage$55.00$49.50$0.00
961075Model 3600 Headstage, 16-Channel, Record Only$1,155.00$1,097.25$0.00
961050Model 3600 Output Cable, for 16-Channel Record Only Headstage$255.00$242.25$0.00
963000Model 3600 Input Cable with Leads, for any 16-Channel Headstage$105.00$94.50$0.00
963100Model 3600 Pin Socket Headstage Adapter for any 16-Channel Headstage$130.00$117.00$0.00
963200Model 3600 Michican Probe Headstage Adapter for any 16-Channel Headstage$155.00$139.50$0.00
955000SciWorks Data Acquisition System, 16-Channel, 400kHz A/D Card, Patch Panel$9,205.00$8,744.75$0.00
956000SciWorks Data Acquisition System, 32-Channel, 1.25MHz A/D Card, Patch Panel$10,525.00$9,998.75$0.00
Prices generated at 3:46 PM on 9/6/2008.
   
ISO 13485:2003 Certified!


SHOPPING CART

YOUR
ACCOUNT
· Mailing List
· Payment Options
SHIPPING &
SERVICE
· Shipping Options
· Return Policy
INTERNATIONAL
CUSTOMERS
· Locate a Dealer
· Pricing & Service
CONTACT
INFORMATION
· Instant Chat
· Phone, Mail & E-Mail
COMPANY
INFORMATION
· About Us
· OEM Products
Copyright © 1996-2008 A-M Systems, Inc.     All Rights Reserved.     Terms of Service     Privacy Policy