Join Our Network of Distributors Worldwide
1-360-683-8300
1-800-426-1306
Vitalograph Pneumotrac Spirometer

Vitalograph Pneumotrac Spirometer


Options:

Summary

The Vitalograph Pneumotrac is an excellent spirometry choice when long-term storage and analysis of patient results are essential. It offers over 30 configurable parameters and storing and trending of test results.

The Vitalograph Pneumotrac features sophisticated Spirotrac software and the unparalleled accuracy of Fleisch pneumotachograph flow measuring technology.

Vitalograph Pneumotrac features:

  • simply plugs into a PC‘s USB port for a low-cost spirometry solution
  • adaptable, interactive, user friendly software for full automation
  • network ready, standardised communications with other databases
  • comprehensive, configurable reports for spirometry sessions and trending
  • intuitive user interface with workflow orientated presentation
  • automatic FEV1 trend chart of actual and normal range data as subject is selected
  • open session, f/v and v/t curves, all test data and test quality in one view
  • choice of attractive incentives
  • spirotrac supports GDT Standard connectivity for EMR systems
  • proven spirometry software with automatic test quality control and trending
  • fully scalable database capacity using powerful Microsoft® SQL server technology
  • links to Vitalograph Over-Read Spirometry QA Service
  • links to practice management systems to automatically transfer subject and test data
  • automatic storage of all test data and events, including calibration log

Description

Vitalograph Pneumotrac Specifications
Size164 mm x 163 mm x 167 mm
Weight0.58 Kg
Operating Temperature Range17°–37°C
Design Limits10°–40°C
Power SupplyFrom USB 2 port, 9 V battery for hygiene fan
Flow Detection PrincipleFleisch type pneumotachograph
Volume DetectionFlow integration sampling @ 100 Hz
Accuracy when in Operating RangeVolumes: Better than ± 3% (Max 8L / Min 0.05L)
Flows: Better than ± 5% (Max 16L/s / Min 0.02L/s)
Linearity: ± 1% in range 0.1 L/s to 16 L/s
Max Test Duration20s FVC; 30s VC
Environmental DataSelectable temperature (built in sensor), barometric pressure, altitude & humidity
Parameters DisplayedUser selectable from: VC, IVC, IC, VT (TV), TLC, RV, IRV, ERV, FRC, FVC, FIVC, FEV1, FEV3, FEV6, FVC, FEV1/VC, FEV1/FVC, FEV3/VC, FEV3/FVC, FEV1/FEV6, FEF75, FEF50, FEF25, FEF25-75, FEF25-75/FVC, FIV1, PIF, FIV1/FIVC, FIF25, FIF50, FIF75, FEF50/FIF50, FET, MVVind, FEV1 Ratio, FEV 0.5, PEF L/min, PEF L/s, FEF 0.2-1.2, FEF75-85%, FEF25%, FEF50%, FEF75%, FMFT, FIF25%, FIF50%, FIF75%, PIF, FEV0.75, Lung Age and more
Test TypesSingle breath tests, flow/volume loops, multi-breath testing, tidal breathing and combined VC/FVC type test methods supported
Predicted Values SelectableERS/ECCS, NHANES, Polgar, Pereira, Berglund, Forsche, Gutierrez, Hedenström, Taiwan, Knudson, Crapo, Hsu, KNLW, Viljanen, SEPAR, Gulsvik, SBPT, Tamura, Ip, Quanjer, Wang, Dockery and more
Performance StandardsISO 26782:2009, ISO 23747:2007, ATS/ERS 2005
Safety StandardsIEC 60601-1:2005
Medical Safety StandardMedical Devices Directive 93/42/EEC 1993 (as amended)
Designed and Manufactured UnderISO 13485:2003, FDA 21CFR820, CMDR